Safety and efficacy of targeting the supplementary motor area with double-cone deep transcranial magnetic stimulation vs figure-eight coil in treatment of obsessive-compulsive disorder with comorbid major depressive disorder

Reza Tadayonnejad,Juliana Corlier,Thomas E Valles,Cole Citrenbaum,Cole Matthews,Evan Einstein,Scott A Wilke,Aaron Slan,Margaret G Distler,Gil Hoftman,Adesewa E Adelekun,Hanadi A Oughli,Michael K Leuchter,Hewa Artin,Ralph J Koek,Nathaniel D Ginder,David Krantz,Thomas Strouse,Andrew F Leuchter
DOI: https://doi.org/10.1016/j.jpsychires.2024.09.026
Abstract:Background and objective: The Supplementary Motor Area (SMA), a relatively large brain structure predominantly located along the interhemispheric fissure, is an established target for repetitive Transcranial Magnetic Stimulation (rTMS) treatment of Obsessive-Compulsive Disorder (OCD). We investigated the feasibility, safety, and efficacy of targeting SMA using a double-cone "deep" TMS coil compared to conventional figure-eight coil for treatment of OCD with comorbid Major Depressive Disorder (MDD). Methods: Sixty-two patients with treatment-resistant OCD and comorbid MDD participated in the study. All patients received high-frequency rTMS over the left dorsolateral prefrontal cortex (DLPFC) with a figure-eight coil (MagVenture B70), followed by 1 Hz rTMS over the bilateral SMA using either the B70 (N = 25) or double-cone deep coil (MagVenture DB80) (n = 23) for 36 treatment sessions. Weekly clinical assessments were conducted. Results: Subjects overall had significant reductions in OCD and depressive symptom severity at the primary endpoint. Subjects stimulated at SMA with the double-cone deep coil had statistically significantly lesser reductions in overall OCD and depression symptom severity compared to the figure-eight group. The intensity of stimulation at SMA was significantly greater with the double-cone deep than figure-eight coil and e-field modeling showed that it affected broader regions beyond SMA (off-target stimulation). There was no significant difference in reported tolerability between groups. Conclusions: SMA stimulation using either a double-cone deep or conventional figure-of-eight coil was safe and was associated with a significant reduction in comorbid OCD and depression symptoms, but the higher intensities of stimulation with the double-cone deep coil used in this study were significantly less clinically beneficial than figure-eight coil stimulation.
What problem does this paper attempt to address?