Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET

Juan J Young,Ryan S O'Dell,Mika Naganawa,Takuya Toyonaga,Ming-Kai Chen,Nabeel B Nabulsi,Yiyun Huang,Emma Cooper,Alyssa Miller,Jessica Lam,Kara Bates,Audrey Ruan,Kimberly Nelsen,Elaheh Salardini,Richard E Carson,Christopher H van Dyck,Adam P Mecca
DOI: https://doi.org/10.2967/jnumed.124.267419
2024-11-01
Abstract:Simplified methods of acquisition and quantification would facilitate the use of synaptic density imaging in multicenter and longitudinal studies of Alzheimer disease (AD). We validated a simplified tissue-to-reference ratio method using SUV ratios (SUVRs) for estimating synaptic density with [11C]UCB-J PET. Methods: Participants included 31 older adults with AD and 16 with normal cognition. The distribution volume ratio (DVR) using simplified reference tissue model 2 was compared with SUVR at short scan windows using a whole-cerebellum reference region. Results: Synaptic density was reduced in AD participants using DVR or SUVR. SUVR using later scan windows (60-90 or 70-90 min) was minimally biased, with the strongest correlation with DVR. Effect sizes using SUVR at these late time windows were minimally reduced compared with effect sizes with DVR. Conclusion: A simplified tissue-to-reference method may be useful for multicenter and longitudinal studies seeking to measure synaptic density in AD.