The use of indocyanine green fluorescence imaging in preventing postoperative bile leakage of the hepaticojejunostomy in robot-assisted pancreatic surgery

Anton F Gijsen,Roelof P H de Vries,Harry G M Vaassen,Robert H Geelkerken,Mike S L Liem,Daan J Lips
DOI: https://doi.org/10.1016/j.hpb.2024.08.013
2024-09-02
Abstract:Background: Postoperative bile leakage (POBL) due to insufficiency of the hepaticojejunostomy (HJ) after pancreatico-duodenectomy (PD) is associated with high morbidity and mortality. The aim of this cohort study was to determine the clinical relevance of ICG in detecting and preventing POBL of the HJ in robotic minimal invasive pancreatic surgery (R-MIPS). Methods: All consecutive robot- and ICG-assisted HJ-anastomoses between 2019 and 2022 were included. Biliary leakage was objectified with near infrared technology. Only clinically relevant POBL were considered in this study. Results: Sixty patients who underwent a PD between 2019 and 2022 were included. In ten patients, fluorescence imaging revealed an intra-operative hepaticojejunostomy insufficiency (HJI). Five of these patients developed POBL despite revision but preventing POBL in five patients. Detection of HJI with ICG predicted POBL with a sensitivity and specificity of 41.6% and 89.6% respectively. There was a significant higher chance of developing a POBL if the hepatic duct diameter was less than 5 mm (relative risk = 4.68 (p = 0.0345)), or if an intra-operative HJI was detected (relative risk = 3.57 (p = 0.009)). Conclusion: ICG is a simple and useful tool for detecting intra-operative bile leakage. This study shows that bile illumination with ICG in R-MIPS could prevent postoperative bile leakage.
What problem does this paper attempt to address?