Sodium Pump of Cultured Guinea Pig Atrial Myocytes

J. Kockskämper,H. Glitsch
DOI: https://doi.org/10.1111/j.1749-6632.1997.tb52269.x
IF: 6.499
1997-11-01
Annals of the New York Academy of Sciences
Abstract:Cardiac atrial cells are frequently used in studies on membrane currents, the most prominent probably being I ~ ( ~ c h ) , but little is known about the NdK pump of these cells. In order to fill this gap we studied the characteristics of I,, the current produced by the atrial Na/K pump, by means of whole-cell recording.’.2 Experiments were performed at 30°C on cultured, isolated guinea pig atrial myocytes (“cardioball~”~) in Na-containing media. Their spherical shape and small size make cardioballs ideally suited for whole-cell recording. Their geometric properties favor the control of the ionic composition of the cell interior, which is of particular importance for measurements of the dependence of I, on [Nali. Low-resistance (1.5-3.5 M a ) patch pipettes contained (in mM): 110 CsCl; 40 NaCl; 10 NaOH; 3 MgCl,; 6 ethylene glycol-bis(P-aminoethyl ether) N,N,N’,N‘-tetraacetic acid (EGTA); 16 N-2-hydroxyethylpiperazine-N’-2-ethanesulfonic acid (HEPES); 10 adenosine 5’-triphosphate (ATP), pH 7.4 (CsOH). The extracellular solution included (in mM): 144 NaC1; 0-10.8 KCI; 5 NiCl2; 2 BaCl,; 1.8 CaC12; 0.5 MgC12; 10 HEPES; pH 7.4 (NaOH). CsCl, BaC12, and NiClz suppressed K and Ca conductances and/or the sarcolemmal NdCa exchange. Rapid changes of extracellular solution (< 1 s) were performed with a multibarreled pipette positioned close to the cell under investigation. Measurements were carried out at 0 mV except for studies on the voltage dependence
What problem does this paper attempt to address?