Abstract:With use of the Anger scintillation camera, the injection of a small bolus containing a large amount of radioactive tracer makes possible visualization of major vascular pathways (11), as well as of the blood supply to certain critical organs (4, 10). We have had the opportunity of applying rapid sequential scintiphotographic technics to the study of renal blood flow in a wide variety of cases. In this report an attempt will be made to indicate the potential usefulness of the procedure in several different clinical situations. Method The Pho Gamma III scintillation camera2 was employed in this study. The patient is placed in the prone position with the camera's detector head situated over the renal area. One hundred microcuries of 197Hg-chlormerodrin is given intravenously, and ten to twenty minutes later sufficient activity is present in the renal cortex to collect 50,000 counts in five to seven minutes. Specific abnormalities are identified on the conventional chlormerodrin study, particularly in cases ...