Efficacy and Safety of Catheter-Based Radiofrequency Renal Denervation in Chinese Patients With Uncontrolled Hypertension: The Randomized, Sham-Controlled, Multi-Center Iberis-HTN Trial

Xiongjing Jiang,Felix Mahfoud,Wei Li,Hui Dong,Jing Yu,Shuhua Yu,Xiaoping Chen,Peijian Wang,Zhiqiang Li,Lucas Lauder,Zhifang Wang,Zheng Ji,Yifei Dong,Bing Han,Zhiming Zhu,Yulin Chen,Jianzhong Xu,Xingsheng Zhao,Weidong Fan,Wen Xie,Brad Hubbard,Xi Hu,Kazuomi Kario,Runlin Gao
DOI: https://doi.org/10.1161/CIRCULATIONAHA.124.069215
IF: 37.8
2024-09-04
Circulation
Abstract:Background: Renal denervation (RDN) can lower blood pressure (BP) in patients with hypertension in both the presence and absence of medication. This is the first sham-controlled trial investigating the safety and efficacy of RDN in China. Methods: This prospective, multicenter, randomized, patient- and outcome-assessor-blinded, sham-controlled trial investigated radiofrequency RDN in patients with hypertension on standardized triple antihypertensive therapy. Eligible patients were randomized 1:1 to undergo RDN using a multi-electrode radiofrequency catheter (Iberis; AngioCare, Shanghai, China) or a sham procedure. The primary efficacy outcome was the between-group difference in baseline-adjusted change in mean 24-hour ambulatory systolic BP from randomization to 6 months. Results: Of 217 randomized patients (mean age, 45.3±10.2 years; 21% female), 107 were randomized to RDN and 110 were randomized to sham control. At 6 months, there was a greater reduction in 24-hour systolic BP in the RDN (-13.0±12.1 mm Hg) compared with the sham control group (-3.0±13.0 mm Hg; baseline-adjusted between-group difference, -9.4 mm Hg [95% CI, -12.8 to -5.9]; P<0.001). Compared with sham, 24-hour diastolic BP was lowered by -5.0 mm Hg ([95% CI, -7.5 to -2.4]; P<0.001) 6 months after RDN, and office systolic and diastolic BP was lowered by -6.4 mm Hg ([95% CI, -10.5 to -2.3]; P=0.003) and -5.1 mm Hg ([95% CI, -8.2 to -2.0]; P=0.001), respectively. One patient in the RDN group experienced an access site complication (hematoma), which resolved without sequelae. No other major device- or procedure-related safety events occurred through follow-up. Conclusions: In this trial of Chinese patients with uncontrolled hypertension on a standardized triple pharmacotherapy, RDN was safe and reduced ambulatory and office BP at 6 months compared with sham. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT02901704.
What problem does this paper attempt to address?