Discordance between Reptilase Time Measured by the Hook Manual Method and the Optical Method in Patients with High Fibrinogen Level

P. Capel,A. Roose,J. Vanderpas
DOI: https://doi.org/10.1055/s-0038-1647132
1989-12-29
Thrombosis and Haemostasis
Abstract:Bothrops athrox venom is mainly used in clinical laboratories to rule out the presence of heparin in samples showing a prolonged thrombin time. The test using this venom is generally designated by a trade name as "reptilase time". We observed an abnormally high reptilase time in samples with high fibrinogen levels using the hook manual method. In such cases a change of turbidity was seen before the detection of the clot. No such delay between the change in turbidity and the detection of the clot was observed with thrombin. In order to define the influence of fibrinogen level on reptilase time, we studied 63 routine samples with fibrinogen levels varying from 1.88 to 9.84 g/1. Cirrhotic patients were discarded in order to avoid samples containing abnormal fibrinogen. Reptilase time was measured with Bothrops Atrox Venom (FTH 50® Stago) and thrombin time with human thrombin (Fibrindex® Ortho) at a final concentration of approximatively 1.3 u/ml. Both reptilase and thrombin times were measured with the hook manual method and with an optical device (Electra® 800 MLA). Fibrinogen concentration was measured using the Clauss method (1) on a KC® device supplied by Hamelung. We observed a surprisingly good correlation between the fibrinogen concentration and the difference between reptilase times measured by the manual hook method and by the optical method (Fig. 1). Although the thrombin time was shorter by the optical method than by the manual hook method, fibrinogen level did not influence the difference between the thrombin times obtained by both methods. Fibrin formation is a process which involves several steps: fibrinopeptide release, longitudinal polymerization, lateral polymerization and gel formation (2). Longitudinal and lateral polymerizations are globally detected by optical devices whereas gel formation is detected by the hook manual method. Thrombin induces the release of fibrinopeptides A and B from fibrinogen whereas reptilase qnly induces fibrinopeptide A release (3). Both reactions are followed by· fibrin polymerization, but in the latter case, lateral polymerization is delayed (3, 4). A network between fibrin fibres results in the formation of a gel. Our observations suggest that fibrinogen, at least in the concentration range studied, has an inhibitory effect on the formation of a fibrin gel induced by reptilase and not on thrombin induced gel formation. Whether this phenomenon is due to an inhibition of lateral polymerization already delayed by the presence of fibrinopeptide B or to an inhibition of fibrin fibres network formation could not be concluded from our experiment. From a practical point of view, in the presence of high fibrinogen and high thrombin time, a high reptilase time measured by the hook manual method does not rule out the presence of heparin. · 0 G)
What problem does this paper attempt to address?