Novel Flowable Hemostatic Agent ActiClot: Efficacy and Safety Assessment in Rat and Porcine Models

Hee-Jung Kim,Su-Kyoung Lee,Yun-Jeh Ko,Soo-Hyeon Jeon,Eun-Jin Kim,Oh-Hyeong Kwon,Yang-Hyun Cho
DOI: https://doi.org/10.3390/jcm13164770
2024-08-14
Abstract:Background/Objectives: This study evaluated the hemostatic performance and safety of ActiClot (ATC), a new flowable hemostatic agent, through in vivo tests. Methods: ATC was compared with the commercially available FLOSEAL®. ATC consists of carboxymethyl starch, thrombin, and sorbitol powders in Syringe I, and a calcium chloride solution in Syringe II. In vivo evaluation used rat liver bleeding and porcine heart bleeding models. Safety was assessed using a rat subcutaneous implantation model. Results: ATC significantly reduced hemostasis time (70.00 ± 7.35 s) compared to gauze control (240.63 ± 32.31 s) in the rat liver model, showing a 70% reduction. There was no significant difference between ATC and FLOSEAL® (58.75 ± 13.42 s). In the porcine heart model, both agents achieved 100% hemostasis within 3 min, with no significant difference in success rates within 2 min (ATC 87.5%, FLOSEAL® 75%). The gauze control group failed in all tests. The rat subcutaneous implantation model showed no visual ATC observation after 48 h, indicating biocompatibility, with no inflammation observed. Conclusions: ATC demonstrated effective hemostatic performance similar to FLOSEAL® in two in vivo models, with faster hemostasis in the rat liver model. It also showed excellent safety and biocompatibility, indicating its potential for surgical and emergency bleeding control.
What problem does this paper attempt to address?