Analysing carbapenemases in hospital wastewater: Insights from intracellular and extracellular DNA using qPCR and digital PCR

Tim Erler,Felix Droop,Christoph Lübbert,Johannes K Knobloch,Laura Carlsen,Cihan Papan,Thomas Schwanz,Janine Zweigner,Jennifer Dengler,Marc Hoffmann,Nico T Mutters,Mykhailo Savin
DOI: https://doi.org/10.1016/j.scitotenv.2024.175344
2024-11-10
Abstract:The widespread dissemination of carbapenem-resistant bacteria in wastewater systems, particularly from clinical sources, poses a significant public health risk. This study assessed the concentrations and distributions of extracellular DNA (exDNA) and intracellular DNA (iDNA) harboring carbapenemase genes in wastewater from six tertiary care hospitals in Germany. We collected a total of 36 samples, comprising six biological replicates from each hospital, and analysed them using quantitative real-time PCR (qPCR) and digital PCR (dPCR). The analysis targeted seven carbapenemase genes: blaNDM, blaKPC, blaIMP, blaVIM, blaOXA-23-like, blaOXA-48-like, and blaOXA-58-like across both DNA fractions. Our results revealed significant variability in the concentrations of exDNA and iDNA across the sampling sites, with iDNA typically present at higher concentrations. Using NanoDrop One spectrophotometry and the Qubit dsDNA kit, exDNA concentrations ranged from 2.7 to 7.7 ng/mL, while Qubit recorded lower values between 1.1 and 4.0 ng/mL. Conversely, iDNA concentrations were markedly higher, spanning from 42.3 to 191.7 ng/mL with NanoDrop and 12.0 to 46.5 ng/mL with Qubit, highlighting the variability between DNA types and quantification methods. Despite its lower concentrations, exDNA comprised up to 18.2 % of total DNA, highlighting its potential role in the horizontal transfer of antimicrobial resistance genes (ARGs). The study detected target ARGs in both DNA fractions at all sites, with notable differences in their concentrations; iDNA consistently exhibited higher levels of ARGs, with the highest concentrations reaching 10.57 ± 0.20 log gene copies per liter (GC/L) for blaVIM in iDNA and 6.96 ± 0.72 log GC/L for blaIMP in exDNA. dPCR demonstrated greater sensitivity than qPCR, especially effective for detecting low-abundance targets like blaOXA-23-like in the exDNA fraction. Additionally, qPCR's susceptibility to inhibition and contamination emphasizes the superior robustness of dPCR. This research highlights the need for improved monitoring and the implementation of advanced treatment technologies to mitigate ARG dissemination in wastewater.
What problem does this paper attempt to address?