EARLY RENAL TRANSPLANT FAILURE ASSOCIATED WITH SUBLIMINAL SENSITIZATION

Z. J. Lucas,N. Coplon,R. Kempson,R. Cohn
DOI: https://doi.org/10.1097/00007890-197012000-00009
1970-12-01
Transplantation
Abstract:SUMMARY A sensitive assay, based on the inhibition of binding of radioiodine-labeled anti-HL-A IgG, was used to measure antibodies against transplantation antigens on donor cells. Low levels of antibodies, not detectable by cytotoxicity assays, are rapidly destructive to renal grafts. The titer of antibody correlated with the severity of early renal failure. High levels of antibody caused immediate anuria (hyperacute rejection). Intermediate titers were associated with immediate diuresis and with graft failure within 24–96 hr (accelerated rejection). Low levels were associated with mild impairment of renal function suggestive of ischemic damage (high output failure). These findings indicate that a substantial number of early failures previously attributed to obscure causes may have been attributable to antibodies not detected by routine tests used for cross matches.
What problem does this paper attempt to address?