Application of visual magnetic navigation system in the distal locking process of tibial intramedullary nail
Hao ZHANG,Li-hai ZHANG,Rui HUANG,Zhi MAO,Li-cheng ZHANG,Yong SUN,Pei-fu TANG
DOI: https://doi.org/10.3969/j.issn.2095-252X.2014.03.015
2014-01-01
Abstract:Objective To retrospectively evaluate the effects of visual magnetic navigation system in the distal locking process of tibial intramedullary nail, to compare the effects with that of the conventional matched target device, and to investigate the effects of magnetic navigation system in the distal locking process of intramedullary nail. Methods From February 2010 to April 2011, 67 patients with tibial shaft fractures who were adopted by our department andtreated with the visual magnetic navigation systemin the distal locking process of intramedullary nailwere selected as the research group, while in the same period 60 patients was treated with the matched target device in the locking process were taken as the control group. The research results were retrospectively analyzed. There were 40 males and 27 females in the research group, with a mean age of ( 37.4±3.8 ) years old. 30 fractures were on the left side, while 37 on the right side. According to the AO classiifcation, there were 33 cases of type A, 19 cases of type B and 15 cases of type C. In the control group, there were 37 males and 23 females with an average age of ( 39.2±4.1 ) years old. 28 fractures were on the left side, while 32 on the right side. According to the AO classiifcation, the type A, type B and type C fractures in the control group were in 29, 14 and 17 cases respectively. The visual magnetic navigation systemwas applied in the distal locking process in the research group, and the conventional matched target devicewas applied in the control group. The time for the distal locking process, the number of screw placements, the number of lfuoroscopy and the fracture healing timein the 2 groups were recorded and compared. Results Thetime for the locking process inthe research group was ( 6.1±1.4 ) min, the number of lfuoroscopy was 0, the number of screw placements was 69, and the fracturehealing timewas ( 15.3±2.1 ) weeks. The time needed for the locking processin the control group was ( 8.3±2.4 ) min, the average number of lfuoroscopy was ( 4.05±2.2 ), the number of screw placements was 71, and the fracture healing time was ( 15.9±2.8 ) weeks. The differences in the duration of locking process andthe number of fluoroscopy andscrew placements werestatistically significant between the 2 groups ( P<0.05 ), and while the differencesin the fracturehealing time were not statisticallysignificant ( P>0.05 ). Conclusions The visual magnetic navigation system appliedin the distal locking process of intramedullary nailcan effectively improve the success rate of thelocking process, and shorten the operationtime while obviously decreasingtheradiation exposure of both doctors and patients. It is superior to the conventional matched target device, and is the new development trend of intramedullary nail navigation technology.