Study on membrane fouling mechanisms and mitigation strategies in a pilot-scale anaerobic membrane bioreactor (P-AnMBR) treating digestate

Luotong Ren,Xiaoguang Chen,Jian Wu,Shenglin Huang,Amankwah Williams,Qianyi Su
DOI: https://doi.org/10.1016/j.watres.2024.122166
2024-07-27
Abstract:Anaerobic Membrane Bioreactor (AnMBR) are employed for solid-liquid separation in wastewater treatment, enhancing process efficiency of digestion systems treating digestate. However, membrane fouling remains a primary challenge. This study operated a pilot-scale AnMBR (P-AnMBR) to treat high-concentration organic digestate, investigating system performance and fouling mechanisms. P-AnMBR operation reduced acid-producing bacteria and increased methane-producing bacteria on the membrane, preventing acid accumulation and ensuring stable operation. The P-AnMBR effectively removed COD and VFA, achieving removal rates of 82.3 % and 92.0 %, respectively. Higher retention of organic nitrogen and lower retention of ammonia nitrogen were observed. The membrane fouling consisted of organic substances (20.3 %), predominantly polysaccharides, and inorganic substances (79.7 %), primarily Mg ions (10.1 %) and Ca ions (4.5 %). To reduce the increased transmembrane pressure (TMP) caused by fouling (a 10.6-fold increase in filtration resistance), backwash frequency experiment was conducted. It revealed a 30-min backwash frequency minimized membrane flux decline, facilitating recovery to higher flux levels. The water produced amounted to 70.3 m³ over 52 days. The research provided theoretical guidance and practical support for engineering applications, offering practical insights for scaling up P-AnMBR.
What problem does this paper attempt to address?