Phase shift migration based plane-wave imaging of cortical bone
Yun-Yun Zhang,Yi-Fang Li,Qin-Zhen Shi,Le-Xiu Xu,Fei Dai,Wen-Yu Xing,De-An Ta,Zhang Yun-yun,Li Yi-fang,Shi Qin-zhen,Xu Le-xiu,Dai Fei,Xing Wen-yu,Ta De-an,,
DOI: https://doi.org/10.7498/aps.72.20230581
IF: 0.906
2023-01-01
Acta Physica Sinica
Abstract:Cortical bone, a highly attenuated, anisotropic, and multilayered biological medium with high acoustic impedance, presents significant challenges for high-frequency ultrasound to penetrate its complex structure and acquire high-quality images. The conventional method of using a uniform sound velocity in ultrasound dynamic focus imaging is limited by emission energy and frame rate, hindering accurate and rapid reconstruction of multilayer structures and impeding clinical applications. To address these challenges, this study proposes a novel approach, called the phase shift migration-based plane-wave bone imaging via velocity inversion (PSM-PW-VI), that enables accurate and rapid imaging of multilayer structures in cortical bone. The PSM-PW-VI approach deploys two identical line array probes placed in parallel alignment on both sides of the cortical bone for data acquisition. First, the ultrasound velocity distribution in the imaging region is obtained using ultrasound travel time inversion. Next, two images corresponding to the upper and lower probes are acquired in parallel in the frequency domain, employing a phase shift migration-based coherent plane-wave compounding method. Finally, the two images are merged to generate a complete ultrasound image of the cortical bone. Wave propagation in cortical bone is simulated using the open source toolbox k-wave in MATLAB. Ex-vivo experiments were conducted on 2.5-mm-thick Sawbones phantom and 2.45-mm-thick bovine bone plates to evaluate the feasibility of the proposed method, using the Verasonics platform. Simulation, phantom (Sawbones), and ex-vivo experiments validated the effectiveness of the method. Notably, the average error of the thickness was less than 0.2 mm, and the relative error was less than 7% for both three-layer and five-layer cortical bone. The impact of the number of plane wave compounding angles on imaging quality was investigated, revealing that a mere 15 angles are sufficient to produce high-quality images. The influence of the velocity model on imaging accuracy was also examined since accurate sound velocity estimation is crucial for obtaining high-quality images of cortical bone. Finally, the performance of PSM-PW-VI and PSM-SA in imaging depth and efficiency was compared. The results demonstrate that the proposed PSM-PW-VI method offers significant improvements in terms of temporal resolution, data storage and processing quantity, emission energy, and imaging depth. Collectively, the experimental findings validate the effectiveness of the proposed method as an accurate and efficient ultrasound imaging tool for cortical bone, with substantial implications for the advancement of ultrasound bone imaging technology and clinical applications.
physics, multidisciplinary