Experimental and numerical studies on steel liner tray walls under static transverse loads
Florea Dinu,Calin Neagu,Dan Dubina,Mihai Senila,Robert Laszlo,Emilian Ghicioi
DOI: https://doi.org/10.1016/j.engstruct.2024.117666
IF: 5.582
2024-02-25
Engineering Structures
Abstract:Light weight steel-based panels are largely used for the envelope (walls, roofs) of different kind of buildings. They are typically designed from the weather-related conditions of the site (climatic actions, thermal comfort). Despite their low weight, they have adequate load carrying capacities under transverse loads. However, under extreme loading conditions, like the high intensity pressures associated with external explosions, the panels can be heavily damaged or detached from the structure. The study presented in the paper describes the results obtained on liner tray walls tested for transverse loading until complete failure. The test program included also shear tests on end fastenings. The liner trays were arranged as single span systems supported on side beams and loaded at the mid-span. After a quasi-linear response, the maximum flexural strength is reached. Then, due to a local instability, there is a drop in capacity, followed by an increase in response capacity due to development of catenary forces. If the end fasteners have adequate resistance, the ultimate capacity in the catenary stage can be significantly higher than the peak flexural capacity. The ultimate capacity depends also on the in-plane stiffness of the support columns.
engineering, civil
What problem does this paper attempt to address?