Right trace wrong place: a normal capnography trace despite the tip of the tracheal tube existing outside the airway

A Karmakar,M J Khan,N A H Shallik,A H M N Moustafa,Y M R A Toble,G F Strandvik
DOI: https://doi.org/10.1002/anr3.12313
2024-07-10
Abstract:Head and neck trauma can result in difficult airway management. A 25-year-old male required emergency tracheal intubation on arrival to the emergency department following a motorbike accident. Despite the presence of a normal capnography a computed tomography scan demonstrated a tracheal opening, an extra-tracheal position of the distal end of the tracheal tube, and extensive subcutaneous emphysema. The tube was re-directed into the trachea and the tracheal injury was surgically repaired. This case highlights that the presence of a normal capnograph does not necessarily mean that the distal end of the tracheal tube resides within the airway.
What problem does this paper attempt to address?