Casein/ferric chloride/polyvinyl alcohol composite for specific in-syringe colorimetric detection of formaldehyde in Hevea brasiliensis latex

Nuryanee Hama,Wilairat Cheewasedtham,Thitima Rujiralai
DOI: https://doi.org/10.1007/s00604-024-06491-1
2024-06-26
Abstract:A new, simple, and selective colorimetric method of determining formaldehyde in Hevea brasiliensis latex was developed by using a casein/ferric chloride/polyvinyl alcohol hydrogel composite (casein/FeCl3/PVA) in a modified Leach test. Under heating, formaldehyde reacted with 8% casein in the presence of 0.1% FeCl3 and 4.3% HCl (v/v) entrapped in a 30% PVA hydrogel packed in a syringe. A purple-colored product was formed with a maximum absorbance of 525 nm. The color change was evaluated at the color detection zone indicated on the the syringe. The %magenta values were easily evaluated by using a mobile phone application and employed to determine formaldehyde content. The casein/FeCl3/PVA composite gave a readable response in a formaldehyde detection range from 0.04 to 0.80% with a linear response between %magenta and formaldehyde concentration (R2 = 0.9955). The detection limit was 0.032%, and precisions were in the range 0.67-4.94%. The casein/FeCl3/PVA composite was applied to the analysis of ammonia-preserved latex samples, and recoveries of formaldehyde from samples spiked at 0.1, 0.3, and 0.5% ranged from 81.55 to 99.51% (RSDs ≤ 5.41%). The recoveries and precision of the proposed method were comparable with those of high-performance liquid chromatography (HPLC). The developed method was also selective, showing no interference from other latex preservatives, i.e., phenol, ammonia, or tetramethylthiuram disulfide.
What problem does this paper attempt to address?