Safety of synchronous prophylactic ablation of the anterior saphenous vein in patients undergoing great saphenous vein thermal ablation- 6 months follow-up data of the SYNCHRONOUS study

Carmen K Dietrich,Tobias Hirsch,Karsten Hartmann,Thomas Mattausch,Hans-Christian Wenzel,Philipp Zollmann,Jürgen Veltman,Thomas K Weiler,Guido Lengfellner,Lars Müller,Markus Stücker,Felizitas Pannier,Lorenz Uhlmann,Christine Müller-Christmann
DOI: https://doi.org/10.1177/02683555241257840
Phlebology
Abstract:Background: The SYNCHRONOUS-study investigates simultaneous ASV-ablation with great saphenous vein (GSV) treatment in endovenous laser ablation (EVLA) for preventing varicose vein recurrence. This sub-study examines complication rates associated with prophylactic ASV-ablation. Methods: Among 1173 patients with refluxing GSV, 604 underwent GSV-ablation only, and 569 received additional ASV-ablation. Complication rates were compared over 6 months. Results: Approximately 80% of patients were complication-free with minor bruising and dysesthesia being most common complications. After 6 months, additional prophylactic ASV-ablation did not increase the rate of complications compared to GSV-only treatment. Conclusion: The 6-months follow-up data suggests that prophylactic ASV-closure, alongside GSV-treatment, is safe, with similar complication rates to GSV-only EVLA.