Ventricular assist device support in paediatric patients with restrictive cardiomyopathy - Clinical outcomes and haemodynamics
Sofie Rohde,Oliver Miera,Eugen Sandica,Rachele Adorisio,Diana Salas-Mera,Dominik Wiedemann,Joanna Sliwka,Antonio Amodeo,Can Gollmann-Tepeköylü,Carlo Pace Napoleone,Emanuela Angeli,Kevin Veen,Theo de By,Bart Meyns
DOI: https://doi.org/10.1093/ejcts/ezae277
IF: 4.534
2024-07-19
European Journal of Cardio-Thoracic Surgery
Abstract:Abstract OBJECTIVES Restrictive cardiomyopathy is rare and is generally associated with worse clinical outcomes compared to other cardiomyopathies. Ventricular assist device support for these children is seldom applied and often hampered by the surgical difficulties. METHODS All paediatric (<19 years) patients with a restricted cardiomyopathy supported by a ventricular assist device from the EUROMACS database were included and compared to patients with a dilated cardiomyopathy (retrospective database analyses). Participating centres were retrospectively contacted to provide additional detailed echo and Swan Ganz measurements to analyse the effect of ventricular assist device support on pulmonary artery pressure and right ventricular function. RESULTS Forty-four paediatric ventricular assist device-supported patients diagnosed with restricted cardiomyopathy were included, with a median age at implantation of 5.0 years. Twenty-six of the 44 patient with a restricted cardiomyopathy survived to transplantation (59.1%), 16 died (36.4%) and 2 are still on ongoing VAD support (4.5%) after a median duration of support of 95.5 days (IQR 33.3–217.8). Transplantation probability after 1 and 2 years of ventricular assist device support in patients with a restricted cardiomyopathy were comparable to patients with a dilated cardiomyopathy (52.3% vs 51.4% and 59.5% vs 60.1%, p = 0.868). However, mortality probability was higher in the restricted cardiomyopathy cohort (35.8% vs 17.0% and 35.8% vs 19.0%, p = 0.005). Adverse event rates were high (CVA in 31.8%, pump thrombosis in 29.5%, major bleeding 25.0%, eventual biventricular support in 59.1%). In the atrially cannulated group, CVA and pump thrombosis occurred in twice as much patients (21.1% vs 40.0%, p = 0.595 and 15.8% vs 40.0%, p = 0.464; probably non-significant due to the small numbers). Pulmonary arterial pressures improved after implantation of a ventricular assist device, and six patients who were initially labelled as ineligible due to pulmonary hypertension could eventually be transplanted. CONCLUSIONS Ventricular assist device support in children with a restricted cardiomyopathy is rarely performed. Mortality and adverse event rates are high. On the other hand, survival to cardiac transplantation was 59.1% with all patients surviving the first 30 days after cardiac transplantation. Pulmonary arterial pressures improved while on support, potentially making cardiac transplantation a viable option for previously ineligible children.
surgery,cardiac & cardiovascular systems,respiratory system