Testing of Refrigeration Compressors without Condensation

R. Dirlea,J. Hannay,J. Lebrun
Abstract:This study presents the design procedure and the experimental results obtained on a new test bench for refrigeration compressors. The main components of the plant are: the compressor to be tested, a water cooled heat exchanger, an expansion valve and a refrigerant vesseL The test bench can be used for: performance evaluation of the compressor (refrigerant flow rate can be found on a heat balance on the gas cooler and after it can be converted to cooling capacity), long live tests and quality control for compressors. The advantages of a« fully gas cycle» are: low energy consumption refrigerant charge of the plant, small inertia of the plant. AU global heat transfer coefficient cspecific heat h specific enthalpy Mmass M mass flow rate ppressure Q heat flow rate Ssurface t temperature U internal energy vspecific volume Vvolume Vvolumetric flow rate W -power consumption NOMENCLATURE Greek: .1.,8 difference .1.8m mean log temperature difference s efficiency y isentropic coefficient -r -time pdensity INTRODUCTION Index: amb ambient cp compressor cr critical exexhaust HE heat exchanger HP high pressure side is isentropic LP low pressure side R refrigerant susupply swswept vol volumetric wwater Performance evaluation of refrigeration compressors include estimation of cooling capacity for given setpoints. International Standard ISO 917 [I] describes 9 test methods for the determination of the cooling capacity: A. secondary fluid calorimeter in suction line B. flooded system refrigerant calorimeter in suction line C. dry system refrigerant calorimeter D refrigerant vapour flow meter in the suction line or in the discharge line E. refrigerant liquid flowmeter F. water cooled condenser G. partial condensation of refrigerant H. calorimeter in the discharge line For methods A, Band C, the cooling capacity is found by direct measurement (heat supplied to the evaporator). Methods D and E allow a direct measurement of refrigerant flow rate. Methods F, G and H estimate the refrigerant flow rate using an energy balance. Consequently, for methods D to H, the cooling capacity is found using the thermodynamic properties of the fluid. The criteria of an efficient test bench for compressors should be: • good precision • facility of control • low energy consumption • small inertia (test point and steady sate conditions should be reached as quickly as possible)
What problem does this paper attempt to address?