Towards long-term operation of flow-electrode capacitive deionization (FCDI): Optimization of operating parameters and regeneration of flow-electrode

Wanni Zhang,Wenchao Xue,Chunpeng Zhang,Kang Xiao
DOI: https://doi.org/10.1016/j.heliyon.2024.e24940
IF: 3.776
2024-01-20
Heliyon
Abstract:This study systematically optimized the key operating parameters and interpreted their effecting mechanisms in a flow-electrode capacitive deionization (FCDI) system. The optimal voltage, activated carbon electrode content, electrolyte concentration, feedwater flowrate, and electrode flowrate for desalinating low salinity feedwater (1.0 g L-1 NaCl) were determined to be 1.8 V, 2.0 wt%, 10.0 g L-1, 80 mL min-1, and 60 mL min-1, respectively. The variations of the above parameters can affect the system conductivity, the thickness and stability of the electric double layers, and/or the degree of concentration polarization, thereby influencing the desalination performance. Moreover, a sensitivity analysis identified the operating voltage as the dominant parameter with the most significant influence on the FCDI system. Subsequently, a long-term operation was carried out under single-pass mode. The results showed that the lab-scale FCDI system was able to constantly maintain the desalination efficiency of 1.0 g L-1 feedwater (NaCl) at 40-60 % for multiple operating cycles. Over 99.8 % of electrode material regeneration and desalination efficiency recovery was able to be obtained during a 60-h operation, demonstrating that the FCDI system showed strong stability and long-term operation potential.
What problem does this paper attempt to address?