Diagnostic performance of cross-priming amplification-based lateral flow assay (CPA-LFA) and real-time PCR for koi herpesvirus (KHV) detection

Guk Hyun Kim,Ye Jin Jeong,Yu Gyeong Jeon,Yun Jung Yang,Joon Gyu Min,Do-Hyung Kim,Kwang Il Kim
DOI: https://doi.org/10.1016/j.jviromet.2024.114890
Abstract:Epizootics of Koi herpesvirus (KHV) cause mass mortality in koi carp (Cyprinus rubrofuscus) and common carp (Cyprinus carpio) worldwide. Rapid and accurate virus detection technology is crucial for preventing pathogen spread and minimizing damage. Although several diagnostic assays have been developed for KHV, the analytical and diagnostic performance of the detection methods has not been evaluated. In this study, we developed and validated the diagnostic performance of two molecular diagnostic assays, cross-priming amplification-based lateral flow assay (CPA-LFA) and TaqMan probe-based real-time polymerase chain reaction (PCR). To detect KHV, primers and probe were designed based on the thymidine kinase (TK) genes. The detection limits of developed CPA-LFA and real-time PCR assays were determined to be 675.69 copies/μL and 8.384 copies/μL, respectively. The diagnostic sensitivity and specificity of the developed assay were determined using fish samples (n = 179). CPA-LFA was found to be 93.67% and 100%, respectively, and real-time PCR was found to be 100% and 100%, respectively. Therefore, the newly developed CPA-LFA and real-time PCR assays accurately and rapidly detect KHV. CPA-LFA is particularly suitable for point-of-care diagnosis because of its simple diagnostic process, and real-time PCR analysis is most suitable for precise diagnosis because it can detect low viral loads.
What problem does this paper attempt to address?