Measurement of Pre- or Post-Filter-Ionised Calcium Concentration during Continuous Veno-Venous Haemofiltration

C. Anstey
DOI: https://doi.org/10.1159/000453445
2016-12-13
Blood Purification
Abstract:and replace both calcium and magnesium as necessary [1] . With the local discontinuation of the 14 mmol/l citrate solution and the subsequent use of first an 18 mmol/l and now a 15 mmol/l citrate solution, we see no practical requirement to sample post-filter blood; we, however, agree that such measurement may be necessary in the context of poor filter survival, for example, less than 24 h. At present, using a 15 mmol/l solution, our filters have a median survival of 66 h [1] . Our study was primarily concerned with the biochemical abnormalities associated with the different electrolyte compositions of the 2 fluids, notably the occurrence of a non-respiratory alkalemia with the 18 mmol/l solution. It also dealt with the effect that those differences had in patients over time – in those who were functionally anephric and hence unable to renally compensate for disturbances in their major extracellular electrolytes [1, 3] . In our study, filter survival was an interesting but only a secondary concern. Finally, on an issue related to the use of citrate as an anticoagulant, I am motivated to make a remark. It is an erroneous and common misconception to state that citrate is metabolised to bicarbonate. In the Krebs Cycle, citrate is metabolised to carbon dioxide with the coproduction of NADH [5] . Dear Editor, Thank you for publishing the results of our recent prospective, randomised, controlled study and for the commentary by Jacobs et al. in the same issue [1, 2] . In that commentary, the authors raise the issue of the measurement and control of postfilter-ionised calcium concentrations as a means of enhancing filter survival. When we first began using regional citrate anticoagulation as our preferred method of continuous renal replacement therapy approximately 9 years ago, we were using a proprietary 14 mmol/l pre-filter substitution solution as regional citrate anticoagulation for a continuous veno-venous haemofiltration circuit at a rate of 2,000 ml/h [3] . At that time, we sampled post-filter blood for both clearance studies and adequacy of anticoagulation and invariably found that the post-filter [ICa 2+ ] was less than 0.5 mmol/l and that our circuits lasted well. Since then for both purely practical safety reasons around the issues associated with drawing blood from a pressurised circuit using a sharp needle and in accordance with the local Health Department policy around preventing needle stick injuries [4] , we have largely abandoned the practice. We do, however, continue to monitor serum-ionised calcium regularly by safely drawing blood from the indwelling intra-arterial cannula circuit Received: October 6, 2016 Accepted: November 15, 2016 Published online: December 13, 2016
What problem does this paper attempt to address?