2D Z-scheme ZnIn2S4/g-C3N4 heterojunction based on photoelectrochemical immunosensor with enhanced carrier separation for sensitive detection of CEA

Yiran Bo,Linrong Li,Pei Miao,Chengfang Li,Jing Chang,Yang Zhang,Yanfeng Lv,Xiaofeng Yang,Jing Zhang,Mei Yan
DOI: https://doi.org/10.1016/j.bios.2023.115926
2024-03-01
Abstract:Semiconducting materials based on photoelectrochemical (PEC) sensors have been widely utilized for detection. Meanwhile, the sensitivity of the PEC sensor was limited by low-efficiency carrier separation. Thus, a novel sandwich-type PEC bioimmunosensing based on 2D Z-scheme ZnIn2S4/g-C3N4 heterojunction as a photosensitive material and BiVO4 as a photoquencher was designed for the sensitive detection of carcinoembryonic antigen (CEA). Firstly, the 2D ZnIn2S4/g-C3N4 structure provided a multitude of activated sites which facilitated the loading of the capture antibody (Ab1). Secondly, the Z-scheme heterojunction had a high redox capacity while promoting the rapid separation and migration of photogenerated electron-hole pairs (e-/h+). Thus it was able to consume more electron donors to a certain extent, resulting in a higher initial photocurrent. In addition, BiVO4 with large spatial potential resistance was introduced for the first time to realize signal amplification. BiVO4 could not only compete with substrate materials for electron donors, but also effectively prevent electron donors from contacting the substrate, further reducing the photocurrent signal. Under optimized conditions, the sensor had a favorable detection range (0.0001-100 ng/mL) to CEA and a low detection limit of 0.03 pg/mL. With high specificity, excellent stability, and remarkable reproducibility, this sensor provided a new perspective for constructing accurate and convenient PEC immunosensor for bioanalysis and early disease diagnosisdisease diagnosis.
What problem does this paper attempt to address?