DESIGN AND OPTIMIZATION OF CAPILLARY TUBE- SUCTION LINE HEAT EXCHANGERS

G. Jain,C. Bullard
Abstract:The effect of capillary tube-suction line heat exchanger (ctslhx) geometry on system performance was explored at various design and off-design conditions by embedding it in a system model. A detailed finite-volume model of the capillary tube and suction line, capable of handling all the phase-change complexities was used. All the ctslhx configurations considered meet the design constraints and didn’t affect the design COP very much. Captubes with large inlet sections and relatively small outlets were found to give best performance at all the simulated off-design perturbations.
What problem does this paper attempt to address?