Deep Learning-Based T2-Weighted MR Image Quality Assessment and Its Impact on Prostate Cancer Detection Rates

Yue Lin,Mason J Belue,Enis C Yilmaz,Stephanie A Harmon,Julie An,Yan Mee Law,Lindsey Hazen,Charisse Garcia,Katie M Merriman,Tim E Phelps,Nathan S Lay,Antoun Toubaji,Maria J Merino,Bradford J Wood,Sandeep Gurram,Peter L Choyke,Peter A Pinto,Baris Turkbey
DOI: https://doi.org/10.1002/jmri.29031
Abstract:Background: Image quality evaluation of prostate MRI is important for successful implementation of MRI into localized prostate cancer diagnosis. Purpose: To examine the impact of image quality on prostate cancer detection using an in-house previously developed artificial intelligence (AI) algorithm. Study type: Retrospective. Subjects: 615 consecutive patients (median age 67 [interquartile range [IQR]: 61-71] years) with elevated serum PSA (median PSA 6.6 [IQR: 4.6-9.8] ng/mL) prior to prostate biopsy. Field strength/sequence: 3.0T/T2-weighted turbo-spin-echo MRI, high b-value echo-planar diffusion-weighted imaging, and gradient recalled echo dynamic contrast-enhanced. Assessments: Scans were prospectively evaluated during clinical readout using PI-RADSv2.1 by one genitourinary radiologist with 17 years of experience. For each patient, T2-weighted images (T2WIs) were classified as high-quality or low-quality based on evaluation of both general distortions (eg, motion, distortion, noise, and aliasing) and perceptual distortions (eg, obscured delineation of prostatic capsule, prostatic zones, and excess rectal gas) by a previously developed in-house AI algorithm. Patients with PI-RADS category 1 underwent 12-core ultrasound-guided systematic biopsy while those with PI-RADS category 2-5 underwent combined systematic and targeted biopsies. Patient-level cancer detection rates (CDRs) were calculated for clinically significant prostate cancer (csPCa, International Society of Urological Pathology Grade Group ≥2) by each biopsy method and compared between high- and low-quality images in each PI-RADS category. Statistical tests: Fisher's exact test. Bootstrap 95% confidence intervals (CI). A P value <0.05 was considered statistically significant. Results: 385 (63%) T2WIs were classified as high-quality and 230 (37%) as low-quality by AI. Targeted biopsy with high-quality T2WIs resulted in significantly higher clinically significant CDR than low-quality images for PI-RADS category 4 lesions (52% [95% CI: 43-61] vs. 32% [95% CI: 22-42]). For combined biopsy, there was no significant difference in patient-level CDRs for PI-RADS 4 between high- and low-quality T2WIs (56% [95% CI: 47-64] vs. 44% [95% CI: 34-55]; P = 0.09). Data conclusion: Higher quality T2WIs were associated with better targeted biopsy clinically significant cancer detection performance for PI-RADS 4 lesions. Combined biopsy might be needed when T2WI is lower quality. Level of evidence: 2 TECHNICAL EFFICACY: Stage 1.
What problem does this paper attempt to address?