Preliminary Experience with a Low-Profile High-Density Braid Occluder for Transcatheter Embolization of Pulmonary Arteriovenous Malformations

Qian Yu,Steven Zangan,Brian Funaki
DOI: https://doi.org/10.1016/j.jvir.2023.09.016
Abstract:This brief report describes safety, technical feasibility, and early treatment effectiveness of the low-profile braided occluder (LOBO; Okami Medical, San Diego, Caliornia) for embolization of 9 pulmonary arteriovenous malformations (PAVMs) in 4 patients (3 female and 1 male; age range: 33 to 63 years; 3 patients showed positive results for hereditary hemorrhagic telangiectasia genes). A total of 10 occluders were deployed in 10 vessels (median treated vessel diameters, 3 and 4 mm for LOBO-3 and LOBO-5 groups, respectively). All devices were successfully deployed into the feeder pulmonary arteries, achieving complete cessation of flow. There were no severe adverse events or device migrations. Available short-term follow-up computed tomography (6 PAVMs: median, 7 months; range, 1.5-7 months) demonstrated complete occlusion without persistence or recanalization. The early experience of embolization of PAVMs using a low-profile braided occluder showed it to be safe and effective. Further studies with larger cohorts and longer follow-up periods are warranted.
What problem does this paper attempt to address?