Trachlight™ guided airway topical anesthesia in children with difficult airways

F. Xue,M. Luo,X. Liao,Y. M. Zhang
DOI: https://doi.org/10.1111/j.1460-9592.2009.02933.x
2009-04-01
Paediatric Anaesthesia
Abstract:placement of the ETT in the trachea is confirmed, the cLMA is removed according to the techniques previously described (5). After local ethics committee approval and written informed consent of parents, we had used this technique in 42 paralyzed anesthetized children aged 6 months to 9 years. The cLMAs of sizes 1.5–3.0 were used by the patients’ weight. In 34 (81%) of 42 patients, the CTM was trans-illuminated without repositioning the cLMA and auxiliary maneuver, in 5 (11.9%) of 42 patients, a positional adjustment was required, and in 3 (7.1%) of 42 patients, a positional and auxiliary maneuvers were required. The trans-illumination of the CTM was impossible in no patient. Following correct trans-illumination of the CTM, intubation was successful in 42 (100%) at the first attempt without the need for further repositioning. The mean time (SD, range) required to successful intubation, defined as the period from initial disconnection of the anesthetic breathing system to start of ventilation through the ETT within the cLMA was 32 (9, 17–45) s. There were no airway complications or hypoxic episodes during cLMA insertion and intubation. A previous work in adults has demonstrated that a lack of control of the distal curve of the wand because of the restrictions imposed by the airway tube is a main reason for low success rate of intubation with a Trachlight via the intact cLMA (8). Our preliminary experience suggests that insertion of the ETT-Trachlight assembly via the modified cLMA with a shortened airway tube can maintain the distal curve of the wand with the metallic stylet and may significantly improve the flexibility of intubation procedure. This makes the alignment of the Trachlight tip with the glottic inlet easier. Our data also shows that trans-illumination of the CTM with a lightwand is a useful indicator that the cLMA and the glottic inlet are accurately aligned for intubation in children. Moreover, the shortened airway tube may provide convenient for successful removal of the cLMA after intubation (5). Therefore, we consider that this technique may be a suitable alternative to fiberoptic guided intubation through the cLMA when equipment is unavailable. The main disadvantage of the technique is that ventilation is not possible during intubation attempts. Moreover, the performance of the technique in pediatric patients with difficult airways is yet to be evaluated. To avoid problems, we suggest practitioners familiarize themselves with the technique on a mannikin and then, in elective anesthetized children before using it for management of pediatric difficult airways. Fu Shan Xue Mao Ping Luo Xu Liao Yan Ming Zhang Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China (email: fruitxue@yahoo.com.cn)
What problem does this paper attempt to address?