Coronary Stent Thrombosis: Insights from the Porcine Coronary Stent Model

H. Lowe,R. Kumar,C. Chesterman,R. G. Fahmy,L. Khachigian
DOI: https://doi.org/10.1055/s-0037-1616158
2001-09-01
Thrombosis and Haemostasis
Abstract:Animal models of coronary stenosis, despite their limitations, can provide valuable mechanistic insights into the pathobiology of human vascular lesions (1). These models may also add to our understanding of the mechanisms underlying coronary stent thrombosis. Metallic stents are deployed during percutaneous transluminal angioplasty to reduce the frequency of restenosis by providing scaffold support and reducing elastic recoil (2). Stent thrombosis in humans is a rare but often catastrophic event, with an incidence rate of 1.4% (3, 4). Stent thrombosis rates of 0.2% have recently been reported in patients on a regimen of clopidogrel, aspirin and heparin (3). The thrombus is thought to originate and extend from the stent struts that remain exposed to flowing blood (5, 6). Surprisingly, coronary stent thrombosis has not been demonstrated histologically to date, despite stenting having largely replaced angioplasty in clinical practice (7). Coronary stent thrombosis has also been observed in pigs, with a frequency of 5.5% (8). This porcine model is gaining increasing popularity for the study of the cellular and molecular mechanisms of in-stent stenosis (1, 8, 9). In contrast to humans, however, aspirin and heparin alone have been the standard treatment in pigs, although more recently ticlopidine has been added (8-10). To approximate the anti-thrombotic regimen in humans, we treated juvenile farm pigs (20-30 kg) with clopidogrel (37.5 mg/day), aspirin (300 mg/day), and a heparin bolus (100 U/kg). Fig. 1A shows a representative section of a stent thrombosis in a pig stented with a 15 mm Crown stent (Cordis Corporation, Warren, NJ, USA) that suffered anterior myocardial infarction and death 18 h post procedure. Thrombus occluded virtually the entire lumen and is clearly seen adjacent to individual stent struts in regions B and C. Figs. 1B and 1C show enlarged images of these areas, photographed using Nomarski differential interference contrast which is a technique particularly suited to visualising biological preparations with highly refractile structures (11). Both of these images demonstrate layered erythrocytes and fibrin strands immediately adjacent to the stent struts, extending into the vessel lumen, thus implicating the stent strut as the nidus for thrombus formation. Although lesion-associated coronary thrombosis has been demonstrated in patients who have suddenly died after coronary angioplasty (12), thrombus associated with stent struts has not been documented histologically. The present observation suggests that in humans, thrombus may originate from the stent struts and progress to the lumen, where it narrows the vessel and leads ultimately to the well-documented sequelae of acute myocardial infarction and death.
What problem does this paper attempt to address?