Formation of disinfection by-products in a UV-activated mixed chlorine/chloramine system
Zhi Liu,Bin Xu,Tian-Yang Zhang,Chen-Yan Hu,Yu-Lin Tang,Zheng-Yu Dong,Tong-Cheng Cao,Mohamed Gamal El-Din
DOI: https://doi.org/10.1016/j.jhazmat.2020.124373
IF: 13.6
2021-04-01
Journal of Hazardous Materials
Abstract:In recent years, ultraviolet (UV) irradiation coupled with chlor(am)ination process is ubiquitous in secondary water supply systems in many cities of China. However, the disinfection by-products (DBPs) formation in a UV-activated mixed chlorine/chloramine system (MCCS) still remains unclear. In this study, the DBPs formation in a UV-activated MCCS was systematically investigated, considering influencing factors including the mass ratios of free chlorine to NH<sub>2</sub>Cl, UV irradiation, pH values, NOM types, Br<sup>-</sup> concentration and toxicity of the DBPs. Results indicated that DBPs formation decreased remarkably as mass ratio of free chlorine to NH<sub>2</sub>Cl changed from 5:0 to 0:5. The DBPs formation in humic acid (HA)-containing water was the highest, followed by those in fulvic acid (FA) and algal organic matter (AOM). Besides, better control of the DBP-related calculated toxicity can be achieved in acidic conditions regardless of the UV irradiation. Furthermore, in the presence of Br<sup>-</sup>, a significant reduction of DBPs formation could be achieved in a UV-activated MCCS. The findings also demonstrated that DBPs formation in real water can be effectively reduced at high UV fluence in a MCCS.
environmental sciences,engineering, environmental