Development of Pluoronic nanoparticles of fluorocoxib A for endoscopic fluorescence imaging of colonic adenomas

Md Jashim Uddin,Hiroaki Niitsu,Robert J Coffey,Lawrence J Marnett
DOI: https://doi.org/10.1117/1.JBO.28.4.040501
Abstract:Significance: Current white light colonoscopy suffers from many limitations that allow 22% to 32% of preneoplastic lesions to remain undetected. This high number of false negatives contributes to the appearance of interval malignancies, defined as neoplasms diagnosed between screening colonoscopies at a rate of 2% to 6%. Aim: The shortcomings of today's white light-based colorectal cancer screening are addressed by colonoscopic fluorescence imaging of preneoplastic lesions using targeted fluorescent agents to enhance contrast between the lesion and the surrounding normal colonic epithelium. Approach: We describe the development of Pluronic® nanoparticles of fluorocoxib A (FA), a fluorescent cyclooxygenase-2 (COX-2) inhibitor that enables targeted imaging of inflammation and cancer in numerous animal models, for endoscopic florescence imaging of colonic adenomas. Results: We formulated FA, a fluorescent COX-2 inhibitor, or fluorocoxib negative control (FNC), a nontargeted fluorophore and a negative control for FA, in micellar nanoparticles of FDA approved Pluronic tri-block co-polymer using a bulk solvent evaporation method. This afforded FA-loaded micellar nanoparticles (FA-NPs) or FNC-loaded micellar nanoparticles (FNC-NPs) with the hydrodynamic diameters ( D h ) of 45.7 ± 2.5 nm and 44.9 ± 3.8 nm and the zeta potentials ( ζ ) of - 1.47 ± 0.3 mV and - 1.64 ± 0.5 mV , respectively. We intravenously injected B6;129 mice bearing colonic adenomas induced by azoxymethane and dextran-sodium sulfate with FA-loaded Pluronic nanoparticles (FA-NPs). The diffusion-mediated local FA release and its binding to COX-2 enzyme allowed for clear detection of adenomas with high signal-to-noise ratios. The COX-2 targeted delivery and tumor retention were validated by negligible tumor fluorescence detected upon colonoscopic imaging of adenoma-bearing mice injected with Pluronic nanoparticles of FNC or of animals predosed with the COX-2 inhibitor, celecoxib, followed by intravenous dosing of FA-NPs. Conclusions: These results demonstrate that the formulation of FA in Pluronic nanoparticles overcomes a significant hurdle to its clinical development for early detection of colorectal neoplasms by fluorescence endoscopy.
What problem does this paper attempt to address?