A novel method for precise detection of allergen‐specific IgE via immobilizing His‐tagged allergens to paper‐based device

Mengda Cao,Xisi Han,Chen Lu,Yujie Wang,Zhiqiang Xu,Shuangxi Wang,Bicong Zhou,Chengwu Zhang,Changmin Yu,Lin Li,Ji‐Fu Wei
DOI: https://doi.org/10.1111/all.14500
IF: 12.4
2020-08-05
Allergy
Abstract:<section class="article-section article-section__supporting"><h2><a class="accordion__control"><span>Supporting Information</span></a></h2><table class="support-info__table table article-section__table"><thead><th>Filename</th><th>Description</th></thead><tbody><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0001-FigS1.tif">all14500-sup-0001-FigS1.tif</a>TIFF image, 63.9 KB </td><td>Fig S1</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0002-FigS2.tif">all14500-sup-0002-FigS2.tif</a>TIFF image, 198 KB </td><td>Fig S2</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0003-FigS3.tif">all14500-sup-0003-FigS3.tif</a>TIFF image, 807.8 KB </td><td>Fig S3</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0004-FigS4.tif">all14500-sup-0004-FigS4.tif</a>TIFF image, 3.1 MB </td><td>Fig S4</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0005-FigS5.tif">all14500-sup-0005-FigS5.tif</a>TIFF image, 1.2 MB </td><td>Fig S5</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0006-FigS6.tif">all14500-sup-0006-FigS6.tif</a>TIFF image, 281.8 KB </td><td>Fig S6</td></tr><tr><td><a href="/action/downloadSupplement?doi=10.1111%2Fall.14500&amp;file=all14500-sup-0007-Supinfo.docx">all14500-sup-0007-Supinfo.docx</a>Word document, 54.8 KB </td><td>Supplementary Material</td></tr></tbody></table><p class="disclaimer_text">Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.</p></section>
immunology,allergy
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the inaccuracy and limitations in the existing allergen - specific IgE (sIgE) detection methods. Specifically: 1. **Limitations of existing methods**: - The existing sIgE detection methods in clinical practice usually rely on fixing allergens on solid - phase carriers through chemical bonds or physical adsorption. However, in these methods, the binding sites of allergens are often ambiguous and uncontrollable (Figure 1A). - Due to the steric hindrance effect, the sIgE - binding epitopes may be covered, resulting in inaccurate sIgE recognition and further leading to misdiagnosis of allergic diseases (References 4 - 6). 2. **Proposed new method**: - The paper proposes a new detection method based on a paper - based device. By modifying Ni - NTA groups on the paper surface to fix recombinant allergen proteins with His - tags (such as rCan f 1), rapid, low - cost and efficient sIgE quantitative detection can be achieved (Figure 1C). - This method can ensure that the sIgE - binding epitopes are not covered, improving the accuracy and specificity of detection (Figure 1B). 3. **Goals and significance**: - This research aims to develop a new technology that can overcome the shortcomings of existing methods, in order to improve the accuracy of sIgE detection, reduce the misdiagnosis rate, and provide a more reliable tool for the diagnosis of allergic diseases. - The new method not only has high sensitivity, selectivity and stability, but also can detect multiple allergens simultaneously in a short time. It is suitable for minimally invasive sampling (such as fingertip blood collection) and has broad application prospects. In summary, this paper attempts to solve the problem of inaccurate detection in existing sIgE detection methods due to improper fixation methods, and proposes a new detection method based on a paper - based device and Ni - NTA/His - tag connection to improve the accuracy and reliability of detection.