Skull Base Cerebrospinal Fluid Leakage Control with a Fibrin-Based Composite Tissue Adhesive

J. Rock,D. H. Sierra,Frederico Castro-Moure,Feng Jiang
DOI: https://doi.org/10.1055/s-2008-1058636
1996-07-01
Skull Base
Abstract:Cerebrospinal fluid (CSF) leaks can be responsible for significant patient morbidity and mortality. While the majority of leaks induced after head trauma will seal without intervention, spontaneous or surgically-induced leaks often require operative repair. Many modifications on standard surgical technique are available for repair of CSF fistulae, but none assures adequate closure. We have studied the efficacy of a novel fibrin-based composite tissue adhesive (CTA) for closure of experimentally-induced CSF leaks in rats. Fistulae were created in two groups of animals. Two weeks after creation of the leaks, the animals were sacrificed and analyzed for persistence of leak. A 58% leakage rate was noted in the control group (n = 12), and no leaks were noted in the experimental group closed after application of CTA to the surgical defect followed by skin closure (n = 11). Comparing the control group to the experimental group, results were statistically significant (p = 0.015). These data suggest that CTA may be effective as an adjunct for the closure of CSF fistulae.
What problem does this paper attempt to address?