Validation and Feasibility of Ultrafast Cervical Spine MRI Using a Deep Learning-Assisted 3D Iterative Image Enhancement System
Hui Yao,Bangsheng Jia,Xuelin Pan,Jiayu Sun
DOI: https://doi.org/10.2147/jmdh.s465002
2024-05-23
Journal of Multidisciplinary Healthcare
Abstract:Hui Yao, Bangsheng Jia, Xuelin Pan, Jiayu Sun Department of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, People's Republic of China Correspondence: Jiayu Sun, Department of Radiology, West China Hospital of Sichuan University, Guoxue Xiang No. 37, Chengdu, Sichuan, 610041, People's Republic of China, Email Purpose: This study aimed to evaluate the feasibility of ultrafast (2 min) cervical spine MRI protocol using a deep learning-assisted 3D iterative image enhancement (DL-3DIIE) system, compared to a conventional MRI protocol (6 min 14s). Patients and Methods: Fifty-one patients were recruited and underwent cervical spine MRI using conventional and ultrafast protocols. A DL-3DIIE system was applied to the ultrafast protocol to compensate for the spatial resolution and signal-to-noise ratio (SNR) of images. Two radiologists independently assessed and graded the quality of images from the dimensions of artifacts, boundary sharpness, visibility of lesions and overall image quality. We recorded the presence or absence of different pathologies. Moreover, we examined the interchangeability of the two protocols by computing the 95% confidence interval of the individual equivalence index, and also evaluated the inter-protocol intra-observer agreement using Cohen's weighted kappa. Results: Ultrafast-DL-3DIIE images were significantly better than conventional ones for artifacts and equivalent for other qualitative features. The number of cases with different kinds of pathologies was indistinguishable based on the MR images from ultrafast-DL-3DIIE and conventional protocols. With the exception of disc degeneration, the 95% confidence interval for the individual equivalence index across all variables did not surpass 5%, suggesting that the two protocols are interchangeable. The kappa values of these evaluations by the two radiologists ranged from 0.65 to 0.88, indicating good-to-excellent agreement. Conclusion: The DL-3DIIE system enables 67% spine MRI scan time reduction while obtaining at least equivalent image quality and diagnostic results compared to the conventional protocol, suggesting its potential for clinical utility. Keywords: cervical spine, magnetic resonance imaging, fast imaging, deep learning Magnetic Resonance Imaging (MRI) of the cervical spine non-invasively delivers high-resolution visuals, capturing subtle changes in both the spinal cord and surrounding tissues. 1,2 It excels in delineating soft tissues such as the spinal cord, nerves, and intervertebral discs. 1 However, it confronts an inherent trade-off: prolonged acquisition time compromises either spatial resolution or signal-to-noise ratio (SNR), thereby limiting its clinical utility. Time-consuming spine MRI increases the likelihood of patient movement, introducing artifacts or blurring into images. 3 Moreover, extended MRI exams pose challenges for patients, especially those experiencing claustrophobia or difficulties in remaining still. Unfortunately, as the primary participants for spinal MRI, seniors or patients with severe spinal disease are more likely to be distressed about staying still for long periods, which further raises the opportunity of motion artifacts during exams. In the past three decades, various acceleration techniques have been introduced in MRI. 4–7 Parallel imaging harnesses multiple receiver coils to simultaneously collect the MRI data. 8 Partial Fourier capitalizes on inherent data redundancy due to Hermitian symmetry, collecting only a fraction of the k-space. 9 Compressed sensing undersamples the k-space leveraging sparsity of images. 10 Nowadays, by integrating these acceleration techniques, routine spine MRI has already trimmed its total acquisition time to approximately 5 minutes without compromising diagnostic performance. 5 However, the footsteps towards faster skeletal imaging should not be ended. Despite the achievement, spine MRI still holds much longer acquisition time compared to CT. Recently, deep learning (DL) assisted image optimization has brought fresh possibilities in medical imaging, especially for MRI. 11 The critical idea of DL approaches is to exploit the empirical information of structures and patterns from previously acquired images. In addition to image quality improvement, a common strategy is to speed up sequences with fewer acquisitions while recovering quality to clinically acceptable standards, using this empirical information. 11 Different technical branches have been established, including DL-based reconstruction and post-processing. The former is currently popular, including algorithms provided by several MR vendors. 12–15 However, reconstruction relies on the uti -Abstract Truncated-
health care sciences & services