Improving the performance of P300-based BCIs by mitigating the effects of stimuli-related evoked potentials through regularized spatial filtering
Ali Mobaien,Reza Boostani,Saeid Sanei
DOI: https://doi.org/10.1088/1741-2552/ad2495
IF: 5.043
2024-02-01
Journal of Neural Engineering
Abstract:Objective:
The P300-based brain-computer interfaces (BCIs) typically employ a visual oddball paradigm, where different objects (linked to specific commands) are randomly and frequently intensified. Upon observing the target object, users experience a elicitation of a P300 event-related potential in their electroencephalography (EEG). However, detecting the P300 signal can be challenging due to its very low signal-to-noise ratio (SNR), often compromised by the sequence of visual evoked potentials (VEPs) generated in the occipital regions of the brain in response to periodic visual stimuli.
The main objective of this study is to investigate how visual evoked potentials (VEPs) impact P300-based BCIs. Subsequently, the study aims to propose a method for EEG spatial filtering to alleviate the effect of VEPs and enhance the overall performance of these BCIs.
Approach:
Our approach entails analyzing recorded EEG signals from visual P300-based BCIs through temporal, spectral, and spatial analysis techniques to identify the impact of VEPs. Subsequently, we introduce a regularized version of the xDAWN algorithm, a well-established spatial filter known for enhancing single-trial P300s. This aims to simultaneously enhance P300 signals and suppress VEPs, contributing to an improved overall signal quality.
Main results:
Analyzing EEG signals shows that VEPs can significantly contaminate P300 signals, resulting in a decrease in the overall performance of P300-based BCIs. However, our proposed method for simultaneous enhancement of P300 and suppression of VEPs has demonstrated improved performance in P300-based BCIs. This improvement has been verified through several experiments conducted with real P300 data.
Significance:
This study focuses on the effects of VEPs on the performance of P300-based BCIs, a problem that has not been adequately addressed in previous studies. It opens up a new path for investigating these BCIs. Moreover, the proposed spatial filtering technique has the potential to further enhance the performance of these systems.
engineering, biomedical,neurosciences