Scanning electrochemical microscopy based irreversible destruction of living cells

Margarita Poderyte,Arunas Ramanavicius,Aušra Valiūnienė
DOI: https://doi.org/10.1016/j.bios.2022.114621
2022-11-15
Abstract:In this research, scanning electrochemical microscopy combined with electrochemical impedance spectroscopy has been applied to irreversible electroporation of active yeast cells by causing cell death. This finding is important for the development of irreversible electroporation technique, which could be suitable for the curing of cancerous tissues, because during this research cell death has been achieved using relatively low ultramicro-electrode (UME) voltage, precisely of 2.0 V vs Ag/AgCl,Cl-sat. It was determined that the irreversibly electroporated area of immobilized yeast cells was located directly below the UME and was of approximately 20 times larger width than the diameter of the UME, leaving undamaged cells out of this area. The ability of SECM to move the UME with high accuracy in x, y, and z directions and the ability to use electrodes of various diameters as well as the fact that the diameter of the electroporated area depends on the diameter of the UME and on the distance between the UME and the surface, what offers the possibility to establish targeted electroporation systems for selective treatment of tissues.
What problem does this paper attempt to address?