Design and analysis of a multi-modal refractive index plasmonic biosensor based on split ring resonator for detection of the various cancer cells

Ali Khodaie,Hamid Heidarzadeh
DOI: https://doi.org/10.1007/s11082-024-07381-9
IF: 3
2024-08-27
Optical and Quantum Electronics
Abstract:This paper introduces an innovative optical biosensor designed for multimode refractive index (MMRI) detection, employing split ring resonator (SRR) technology for enhanced sensitivity in cancer cell analysis. The proposed biosensor comprises two concentric SRRs, one resembling a cube and the other a cylinder, each incorporating an air gap. Rigorous analysis and optimization of dimensional parameters were conducted using the finite difference time domain (FDTD) numerical solution method. The simulation results demonstrated that the biosensor achieves exceptional sensitivity and an optimal figure of merit (FOM). Specifically, the first mode of the biosensor exhibited a sensitivity exceeding 80 nm/RIU and an FOM surpassing 20 RIU− 1 , while the second mode demonstrated a sensitivity of 570 nm/RIU and an FOM exceeding 4 RIU− 1 . These results indicate that the first mode benefits from a higher FOM, enhancing precision and accuracy, while the second mode benefits from high sensitivity, enabling the detection of minute refractive index changes. With a primary focus on early cancer cell detection and timely treatment initiation to address the global cancer mortality burden, the biosensor's high-quality factor (Q-factor) and FOM promise significant advancements in cancer diagnostics and therapeutic interventions.
engineering, electrical & electronic,optics,quantum science & technology
What problem does this paper attempt to address?