Novel and Legacy Poly- and Perfluoroalkyl Substances (pfass) in Indoor Dust from Urban, Industrial, and E-Waste Dismantling Areas: the Emergence of PFAS Alternatives in China.
Bo Zhang,Yuan He,Yingyan Huang,Danhong Hong,Yiming Yao,Lei Wang,Wenwen Sun,Baoqin Yang,Xiongfei Huang,Shiming Song,Xueyuan Bai,Yuankai Guo,Tao Zhang,Hongwen Sun
DOI: https://doi.org/10.1016/j.envpol.2020.114461
IF: 8.9
2020-01-01
Environmental Pollution
Abstract:With the phase out of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), the composition profiles of poly- and perfluoroalkyl substance (PFAS) in our living environment are unclear. In this study, 25 PFASs were analyzed in indoor dust samples collected from urban, industrial, and e-waste dismantling areas in China. PFOS alternatives, including 6:2 chlorinated polyfluorinated ether sulfonate (6:2 Cl-PFESA) (median: 5.52 ng/g) and 8:2 chlorinated polyfluorinated ether sulfonate (8:2 Cl-PFESA) (1.81 ng/g), were frequently detected. By contrast, PFOA alternatives, such as hexafluoropropylene oxide dimer acid (HPFO-DA, Gen-X) and ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA), were not found in any of the dust samples. As expected, all legacy PFASs were widely observed in indoor dust, and 4 PFAS precursors were also detected. Dust concentrations of 6:2 Cl- PFESA were strongly correlated (p < 0.05) with those of 8:2 Cl-PFESA regardless of sampling sites. 6:2 Cl-PFESA was also significantly associated with that of PFOS in industrial and e-waste (p < 0.01) areas. Association analysis suggested that the sources of PFOS and its alternatives are common or related. Although Sigma Cl-PFESA concentration was lower than that of PFOS (17.4 ng/g), industrial areas had the highest 6:2 Cl-PFESA/PFOS ratio (0.63). Composition profiles of PFASs in the industrial area showed the forefront of fluorine change. Thus, the present findings suggested that Cl-PFESAs are widely used as PFOS alternatives in China, and high levels of human Cl-PFESA exposure are expected in the future. Short-chain PFASs (C4-C7) were the predominant PFASs found in dust samples, contributing to over 40% of Sigma total PFASs. Furthermore, perfluoro-1-butanesulfonate/PFOS and perfluoro-n-butanoic acid (PFBA)/PFOA ratios were 2.8 and 0.72, respectively. These findings suggested shifting to the short-chain PFASs in the environment in China. To the authors knowledge this is the first study to document the levels of 6:2 Cl-PFESA, 8:2 Cl-PFESA in indoor dust. (c) 2020 Elsevier Ltd. All rights reserved.