Complex B1+ mapping with Carr-Purcell spin echoes and its application to electrical properties tomography

Santhosh Iyyakkunnel,Matthias Weigel,Carl Ganter,Oliver Bieri
DOI: https://doi.org/10.1002/mrm.29020
Abstract:Purpose: To present a new complex-valued B1+ mapping method for electrical properties tomography using Carr-Purcell spin echoes. Methods: A Carr-Purcell (CP) echo train generates pronounced flip-angle dependent oscillations that can be used to estimate the magnitude of B1+ . To this end, a dictionary is used that takes into account the slice profile as well as T2 relaxation along the echo train. For validation, the retrieved B1+ map is compared with the actual flip angle imaging (AFI) method in a phantom (79 ε0 , 0.34 S/m). Moreover, the phase of the first echo reflects the transceive phase. Overall, the CP echo train yields an estimate of the complex-valued B1+ , allowing electrical properties tomography with both permittivity and conductivity. The presented method is evaluated in phantom scans as well as for in vivo brain at 3 T. Results: In the phantom, the obtained magnitude B1+ maps retrieved from the CP echo train and the AFI method show excellent agreement, and both the reconstructed estimated permittivity (79 ± 3) ε0 and conductivity (0.35 ± 0.04) S/m values are in accordance with expectations. In the brain, the obtained electrical properties are also close to expectations. In addition to the retrieved complex B1+ information, the decay of the CP echo trains also yields an estimate for T2 . Conclusion: The CP sequence can be used to simultaneously provide both B1+ magnitude and phase estimations, and therefore allows for full reconstruction of the electrical properties.
What problem does this paper attempt to address?