Usefulness of the HACOR score in predicting success of CPAP in COVID-19-related hypoxemia

Miguel Filipe Guia,José Pedro Boléo-Tomé,Pasquale Imitazione,Giorgio Emanuele Polistina,Carlos Alves,Oki Ishikawa,Matthew Ballenberger,Bushra Mina,Giuseppe Fiorentino,Antonio Esquinas,Raffaele Scala
DOI: https://doi.org/10.1016/j.rmed.2021.106550
Abstract:Introduction: In COVID-19 associated hypoxemic acute respiratory failure (ARF) without mandatory indication for urgent endotracheal intubation, a trial of CPAP may be considered. We aimed to evaluate HACOR (heart rate, acidosis, consciousness, oxygenation, respiratory rate) score performance in these patients as predictor of CPAP failure. Methods: Prospective observational multicentric study (three centers in different countries), including adult patients with SARS-CoV-2 pneumonia admitted to a respiratory intermediate care unit, presenting PaO2/FiO2 < 300 and PaCO2 < 45 mmHg, who received CPAP. One hour after starting CPAP, HACOR was calculated. Results: We enrolled 128 patients, mean age 61,7 years. Mean HACOR at 1 h after starting CPAP was 3,27 ± 3,84 and mean PaO2/FiO2 was 203,30 ± 92,21 mmHg; 35 patients (27,3 %) presented CPAP failure: 29 underwent oro-tracheal intubation and 6 died due to COVID-19 (all having a do-not-intubate order). HACOR accuracy for predicting CPAP failure was 82,03 %, while PaO2/FiO2 accuracy was 81,25 %. Conclusion: Although HACOR score had a good diagnostic performance in predicting CPAP failure in COVID-19-related ARF, PaO2/FiO2 has also shown to be a good predictor of failure.