Comparison of linear and nonlinear function to describe and predict componential evolution of biomass pyrolysis vapors during condensation in a tubular indirect heat exchanger

Chu Wang,Yitao Huang,Rui Diao,Xifeng Zhu
DOI: https://doi.org/10.1016/j.biortech.2021.125654
Abstract:A novel experimental method based on the combination of bio-oil composition inversion and function fitting was purposed and verified for describing the componential evolution curves during the liquefaction of biomass pyrolysis vapors. The evolution curves of representative condensable components were fitted by linear and Slogistic function in the short, middle and long three condensing fields. Linear function exhibited a significant effectiveness for the description and prediction of low-boiling water and furfural and the relative deviations were no more than 5% between actual values in long condenser and predictive values from the elongation of curves in short and middle condensers. For high-boiling phenolic compounds, linear function failed to fit their evolutions in long condenser but Slogistic fitting remained effective despite the relative deviation increasing to about 10%. This investigation provided a unique and effective prediction method for the vapor evolution in industrial shell and tube heat exchanger according to laboratory-scale experiment.