0308 Non-Contact Sleep Monitoring with a Depth Camera: Morphology Similarity Between a Touchless Flow Signal and RIPflow

Paul Addison,Andre Antunes,Dean Montgomery,Philip Smit,Ulf Borg,Lara Brewer,Robert Farney,Krishna Sundar
DOI: https://doi.org/10.1093/sleep/zsae067.0308
IF: 6.313
2024-04-20
SLEEP
Abstract:Abstract Introduction We have developed a non-intrusive sleep monitoring technology based on data from a commercially available depth sensing camera [Intel RealSenseTM D415, Intel, Santa Clara, CA]. This non-contact, or touchless, technology allows continuous respiratory monitoring without attaching probes to the patient. We have noticed a strikingly similar morphology between the touchless flow signal, NCMflow, derived from the depth camera and the RIPflow signal derived from the chest and abdomen respiratory inductance plethysmography (RIP) bands. Here we report on a preliminary quantitative assessment of this morphological similarity between the two signals. Methods For this proof-of-principle study, we analyzed a patient data set acquired continuously during a 9-hour sleep study at the Sleep | Wake Center at the University of Utah, where informed consent was given. Depth data was acquired with the depth camera placed approximately 1.1m above the torso of the patient. A patient with severe sleep apnea (AHI of 74/hr) was selected to compare NCMflow and RIPflow, and we examined both the concordance and the Pearson coefficient, which are measures of the mutual trending and linear correlation between the two signals respectively. The concordance was examined in two distinct timescales (1 and 2 seconds), which allowed for intra-breath morphology analysis, using a data exclusion zone of 10% to account for background signal noise. Both concordance and Pearson coefficient of linear correlation were calculated over the full 9 hours of the sleep study (including sleep and wake periods). Results The concordance for timescales of 1 and 2 seconds were 0.93 and 0.95 respectively, (where complete concordance would equal 1.00 and correspond to perfect co-trending). The corresponding Pearson R value was 0.90, (out of a maximum achievable value of 1.00 corresponding to perfect linear correlation between the signals). Conclusion The high values of the concordances and R confirm the excellent match we observe visually between the touchless flow signal, NCMflow, and the RIPflow signal. Our findings strongly support the potential for non-contact continuous monitoring of respiratory disturbances during sleep based on a depth camera system. Future work will aim to determine the viability of developing a touchless sleep scoring methodology. Support (if any) The work was funded by Medtronic.
neurosciences,clinical neurology
What problem does this paper attempt to address?