Mini fluid chAllenge aNd End-expiratory occlusion test to assess flUid responsiVEness in the opeRating room (MANEUVER study): A multicentre cohort study

Antonio Messina,Giulia Lionetti,Lorenzo Foti,Enrico Bellotti,Nicole Marcomini,Gianmaria Cammarota,Victoria Bennett,Laura Saderi,Giovanni Sotgiu,Francesco Della Corte,Alessandro Protti,Manuel I Monge García,Stefano Romagnoli,Maurizio Cecconi
DOI: https://doi.org/10.1097/EJA.0000000000001406
2021-04-01
Abstract:Background: The fluid challenge response in surgical patients can be predicted by functional haemodynamic tests. Two tests, the mini-fluid challenge (mini-FC) and end-expiratory occlusion test (EEOT), have been assessed in a few small single-centre studies with conflicting results. In general, functional haemodynamic tests have not performed reliably in predicting fluid responsiveness in patients undergoing laparotomy. Objective: This trial is designed to address and compare the reliability of the EEOT and the mini-FC in predicting fluid responsiveness during laparotomy. Design: Prospective, multicentre study. Setting: Three university hospitals in Italy. Patients: A total of 103 adults patients scheduled for elective laparotomy with invasive arterial monitoring. Interventions: The study protocol evaluated the changes in the stroke volume index (SVI) 20 s (EEOT20) and 30 s (EEOT30) after an expiratory hold and after a mini-FC of 100 ml over 1 min. Fluid responsiveness required an increase in SVI at least 10% following 4 ml kg-1 of Ringer's solution fluid challenge infused over 10 min. Main outcome measurements: Haemodynamic data, including SVI, were obtained from pulse contour analysis. The area under the receiver operating characteristic curves of the tests were compared with assess fluid responsiveness. Results: Fluid challenge administration induced an increase in SVI at least 10% in 51.5% of patients. The rate of fluid responsiveness was comparable among the three participant centres (P = 0.10). The area under the receiver operating characteristic curves (95% CI) of the changes in SVI after mini-FC was 0.95 (0.88 to 0.98), sensitivity 98.0% (89.5 to 99.6) and specificity 86.8% (75.1 to 93.4) for a cut-off value of 4% of increase in SVI. This was higher than the SVI changes after EEOT20, 0.67 (0.57 to 0.76) and after EEOT30, 0.73 (0.63 to 0.81). Conclusion: In patients undergoing laparotomy the mini-FC reliably predicted fluid responsiveness with high-sensitivity and specificity. The EEOT showed poor discriminative value and cannot be recommended for assessment of fluid responsiveness in this surgical setting. Trial registration: NCT03808753.
What problem does this paper attempt to address?