A multicenter study on two-stage transfer learning model for duct-dependent CHDs screening in fetal echocardiography
Jiajie Tang,Yongen Liang,Yuxuan Jiang,Jinrong Liu,Rui Zhang,Danping Huang,Chengcheng Pang,Chen Huang,Dongni Luo,Xue Zhou,Ruizhuo Li,Kanghui Zhang,Bingbing Xie,Lianting Hu,Fanfan Zhu,Huimin Xia,Long Lu,Hongying Wang
DOI: https://doi.org/10.1038/s41746-023-00883-y
IF: 15.2
2023-08-13
npj Digital Medicine
Abstract:Duct-dependent congenital heart diseases (CHDs) are a serious form of CHD with a low detection rate, especially in underdeveloped countries and areas. Although existing studies have developed models for fetal heart structure identification, there is a lack of comprehensive evaluation of the long axis of the aorta. In this study, a total of 6698 images and 48 videos are collected to develop and test a two-stage deep transfer learning model named DDCHD-DenseNet for screening critical duct-dependent CHDs. The model achieves a sensitivity of 0.973, 0.843, 0.769, and 0.759, and a specificity of 0.985, 0.967, 0.956, and 0.759, respectively, on the four multicenter test sets. It is expected to be employed as a potential automatic screening tool for hierarchical care and computer-aided diagnosis. Our two-stage strategy effectively improves the robustness of the model and can be extended to screen for other fetal heart development defects.
health care sciences & services,medical informatics