Approaches to altering particle distributions in cryo-electron microscopy sample preparation
Ieva Drulyte,Rachel M. Johnson,Emma L. Hesketh,Daniel L. Hurdiss,Charlotte A. Scarff,Sebastian A. Porav,Neil A. Ranson,Stephen P. Muench,Rebecca F. Thompson
DOI: https://doi.org/10.1107/s2059798318006496
2018-05-18
Acta Crystallographica Section D Structural Biology
Abstract:Cryo-electron microscopy (cryo-EM) can now be used to determine high-resolution structural information on a diverse range of biological specimens. Recent advances have been driven primarily by developments in microscopes and detectors, and through advances in image-processing software. However, for many single-particle cryo-EM projects, major bottlenecks currently remain at the sample-preparation stage; obtaining cryo-EM grids of sufficient quality for high-resolution single-particle analysis can require the careful optimization of many variables. Common hurdles to overcome include problems associated with the sample itself (buffer components, labile complexes), sample distribution (obtaining the correct concentration, affinity for the support film), preferred orientation, and poor reproducibility of the grid-making process within and between batches. This review outlines a number of methodologies used within the electron-microscopy community to address these challenges, providing a range of approaches which may aid in obtaining optimal grids for high-resolution data collection.
biochemistry & molecular biology,biochemical research methods,biophysics,crystallography