Non-Intrusive Measurement of Transient Electric Field Distribution Under AC and Impulse Voltages

Hucheng Liang,Boxue Du,Jin Li
DOI: https://doi.org/10.1109/jsen.2020.2994246
IF: 4.3
2020-09-15
IEEE Sensors Journal
Abstract:Grasping the electric field distribution will provide exact information for the design and the safe operation of electrical devices. A simple but effective technique is developed in this paper to measure the transient electric field distribution by fabricating a micro-sized sensor on the grounded (GND) electrode. Both the parameter selection and the fabrication technique are critical for ensuring the non-intrusive measurement. By experiment, the measured electric fields in time domain have exactly the same waveforms as those of the applied AC and impulse voltages, and their spatial distributions are in good agreement with the theoretical calculation results, which proves the correctness and effectiveness of the measurement system. In the future application, the measurement electrodes of the sensor can be designed to be in smaller size and in array form for a more precise measurement. This technique has the potential to be applied in the electric power system for the dynamic monitoring and the defect location of electrical devices.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
This paper aims to solve the problem of accurate measurement of electric field distribution in electrical equipment. Specifically, the author has developed a simple yet effective technique to measure the transient electric field distribution by fabricating micro - sensors on the ground (GND) electrode. The key to this technique lies in parameter selection and manufacturing process to ensure the accuracy of non - invasive measurement. The experimental results show that the electric field waveform measured in the time domain is exactly the same as the applied alternating - current (AC) and impulse voltage waveforms, and its spatial distribution is in good agreement with the theoretical calculation results, which proves the correctness and effectiveness of the measurement system. In addition, this technique is expected to be applied in power systems in the future to realize the dynamic monitoring and defect location of electrical equipment. ### Main contributions of the paper 1. **Non - invasive measurement technique**: A non - invasive technique has been developed that can accurately measure the electric field distribution on the surface of electrical equipment without interfering with the original electric field. 2. **Micro - sensor design**: By fabricating micro - sensors on the ground electrode, the interference to the electric field is reduced and the measurement accuracy is improved. 3. **Experimental verification**: The experimental results show that the measured electric field waveform is consistent with the applied AC and impulse voltage waveforms, and the spatial distribution is also in line with the theoretical calculation results, verifying the effectiveness and accuracy of the measurement system. 4. **Potential for future applications**: This technique can be further optimized in the future. By designing measurement electrodes with smaller sizes and in array forms, it can be applied to dynamic monitoring and defect location in power systems. ### Key techniques and methods - **Sensor structure**: The sensor consists of a dielectric film, a high - dielectric - constant film and six measurement electrodes. - **Working principle**: Using Gauss's theorem, the average electric field strength is calculated by measuring the charging - discharging current. - **Experimental verification**: Experiments were carried out under AC and impulse voltages to verify the feasibility and accuracy of the measurement system. ### Formulas - **Relationship between electric field and electric flux**: \[ E=\frac{D}{\epsilon_0\epsilon_r} \] where \(E\) is the electric field strength (V/m), \(D\) is the electric flux (C/m²), \(\epsilon_0\) is the vacuum dielectric constant, and \(\epsilon_r\) is the relative dielectric constant. - **Relationship between electric flux and surface charge density**: \[ \bar{D}=\sigma=\frac{Q}{S} \] where \(\bar{D}\) is the average electric flux on the measurement electrode (C/m²), \(\sigma\) is the average surface charge density on the measurement electrode (C/m²), \(Q\) is the charge quantity (C), and \(S\) is the area of the measurement electrode (m²). - **Relationship between charge quantity and current**: \[ Q(t)=\int_0^tI(t)dt + Q(0) \] where \(I(t)\) is the charging - discharging current (A) and \(t\) is the time (s). - **Calculation of average electric field strength**: \[ \bar{E}_i=\frac{\epsilon_0\epsilon_r}{S_i}\left(\int_0^tI(t)dt + Q(0)\right) \] where \(\bar{E}_i\) is the average electric field strength on the \(i\) - th measurement electrode (V/m) and \(S_i\) is the area of the \(i\) - th measurement electrode (m²). Through these techniques and methods, this paper has successfully solved the problem of accurate measurement of electric field distribution in electrical equipment and provided strong support for future practical applications.