C-Mod cryo-pump design evaluation

J. Zaks,R. Vieira,H. Savelli,B. LaBombard,J. Irby,P. Titus,R. Childs,A. Zhukovsky,B. Lipshultz
DOI: https://doi.org/10.1109/FUSION.2003.1425878
2003-10-14
Abstract:This paper covers in detail the design and analysis of the new cryo-pump for the Alcator C-Mod tokamak. We focus on detailing the work done to ensure that the cryopump meets all of the technical requirements for this project. In particular, the following topics will be discussed: calculation of cryo-pump pumping speed, sizing of the helium tube, boiling heat transfer of liquid helium inside the tube, cryo-pump protective shelf design/support, design of the supports for the cryo-pump and its components, heat loss thru the supports for the helium tube, number of cryo-pump sections for the ease of installation, cryogenic system design, installation procedure, experiments to qualify the new cryo pump.
What problem does this paper attempt to address?