Uncapped Metered-Dose Inhalers: A Risk for Foreign Body Aspiration. A Case Report and Review of the Literature
Dirk Schürmann,Jacopo Saccomanno,Bettina Temmesfeld-Wollbrück,Martin Witzenrath,Ralf-Harto Hübner
DOI: https://doi.org/10.2147/COPD.S408845
2023-09-01
International Journal of COPD
Abstract:Dirk Schürmann, Jacopo Saccomanno, Bettina Temmesfeld-Wollbrück, Martin Witzenrath, Ralf-Harto Hübner Department of Infectious Diseases, Respiratory Medicine and Critical Care, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health, Berlin, 10117, Germany Correspondence: Dirk Schürmann, Department of Infectious Diseases, Respiratory Medicine and Critical Care, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany, Tel +49 30 450 653318 ; +49 1723871964, Email The risk of foreign body aspiration associated with uncapped handheld metered-dose inhalers (MDIs) is underestimated. We report a case in which a plastic cable clip accidentally lodged in the mouthpiece of an uncapped pressurized MDI was aspirated during its use. A literature search revealed 16 other cases of foreign body aspiration associated with uncapped handheld inhalers, all but one of which were pressurized inhalers. Patients should be informed of the risk of foreign body aspiration associated with uncapped pocket inhalers. The use of an uncuffed armoured tracheal tube with a separate oxygen tubing during flexible bronchoscopy for foreign body removal ensures a safe airway. Foreign bodies that exceed the lumen size of the tracheal tube can be pulled to the distal opening with forceps and removed when the tube is withdrawn. Plain Language Summary: Handheld pocket inhalers have significantly improved the treatment of patients with chronic obstructive pulmonary disease. We report a case in which a plastic cable clip accidentally lodged in the mouthpiece of an uncapped pressurized pocket inhaler was aspirated during its use. Depressing the plunger of the inhaler released the inhalant in a high-velocity spray, which was inhaled with a deep breath while simultaneously aspirating the plastic cable clip. The risk of foreign body aspiration associated with uncapped pressurized metered-dose inhalers is underestimated. Patients using pocket inhalers should be informed of the risk of foreign body aspiration with uncapped inhalers. Inhalers should always be kept capped except during use to prevent small objects from accidentally entering the mouthpiece. The cap of the inhaler mouthpiece should only be removed when the inhaler is used. Foreign bodies that have accidentally become lodged in the mouthpiece of an inhaler and aspirated into the lungs can usually be removed by specialists during a short outpatient procedure. Keywords: foreign body aspiration, metered-dose inhaler, removal of aspirated foreign bodies, uncuffed armoured tracheal tube with separate oxygen tubing Handheld pocket inhalers have significantly improved the treatment of patients with chronic obstructive pulmonary disease (COPD) and bronchial asthma. Proper handling and storage are prerequisites for efficacy and safety. We report a case of foreign body aspiration associated with the use of an uncapped pressurized inhaler. To obtain data on the incidence and relevance of such a rare complication associated with uncapped pocket inhalers, we searched the medical literature for other reported cases. A 45-year old male presented to the emergency department of a tertiary university hospital complaining about worsening respiratory distress after using a pressurized metered-dose salbutamol inhaler one hour earlier. He reported a foreign body sensation below the larynx that started immediately after using the salbutamol inhaler. Since then, the respiratory distress worsened and he began to cough up bloody discolored sputum. Vital parameters were as follows: Blood pressure 131/67 mmHg, breathing rate 22/min, heart rate 103/min. Oxygen saturation was 92% on room air. Auscultation revealed wheezing breath sounds over both lungs. The patient ́s history revealed COPD, with an as needed use of a salbutamol pressurized metered-dose inhaler, and chronic cigarette smoking. Chest x-ray revealed signs of emphysema and no foreign body. Because of the intensive sensation of a foreign body in the patient ́s throat, we performed an emergency flexible bronchoscopy under sedation with midazolam and propofol. A bronchoscopy-guided oral endotracheal intubation was performed using an uncuffed armoured Rüsch BronchoFlex tracheal tube (inner diameter 7.5 mm) with separate oxygen tubing. On inspection of the bronchi, a plastic cable clip (Figure 1) was visualized occluding the terminal right main bronchus. The foreign body was grasped with a foreign body removal forceps and pulled up to the distal end of the endotracheal tube. Since the cable clip was larger than the tube ́s inner diameter, forceps and tube were removed together. After awakening from sedation the patient reported complete resolution of his complaints and was discharged from the hospital two hours later. Figure 1 Plasti -Abstract Truncated-
respiratory system