The displaced polymer clamp entered the duodenum causing an abscess: A case report

Yong Qiang Yang,Wen Bin Gou
DOI: https://doi.org/10.1097/md.0000000000035783
IF: 1.6
2024-02-10
Medicine
Abstract:The Hem-o-lok clip, made from a nonabsorbable polymer, and its predecessor the metal ligation clip have been used widely for laparoscopic or robot-assisted surgery to ligate the cystic duct after a cholecystectomy, to ligate the appendix after an appendectomy, or control hemorrhage or on occasion to occlude a fistula or enterotomy. Displacement of these ligation clips to distant sites is an extremely rare complication in clinical practice. Many previous case reports focused on displacement of metallic clips used to ligate the cystic duct during cholecystectomy into the digestive tract, bile duct, and urinary tract; most cases have occurred several days or months after their application. This process of displacement can on occasion lead to local bleeding or bile leakage if placed in the biliary tree, and the presence of a nonabsorbable foreign body in the lumen of the biliary tree can also lead to the development of choledocholithiasis. Therefore, metallic clips have been replaced by polymer-based ligation clips, which, because they are made of a polymer substance, appear to have a better safety profile in clinical practice. No prior report to the best of our knowledge exists of duodenal erosion by a displaced polymer-based ligation clip after a cholecystectomy. In this report, we describe our diagnosis and treatment of a patient with a polymer-based clip-induced duodenal bulb erosion with a local contained enterically draining abscess.
medicine, general & internal