Percutaneous Transhepatic Cholangiographic Forceps Biopsy in Pathologic Diagnosis for Obstructive Jaundice
韩新巍,李永东,马波,邢古生,吴刚,高雪梅,马南
DOI: https://doi.org/10.3760/j.issn:1005-1201.2004.10.003
2004-01-01
Abstract:Objective To evaluate the technical feasibility and sensitivity of percutaneous transhepatic cholangiographic forceps biopsy in bile duct diseases.Methods Between April 2001 and March 2003,65 consecutive patients (36 men and 29 women; age range 33-88 years,mean 54 years) with obstructive jaundice underwent transluminal forceps biopsy or/and brush during percutaneous transhepatic cholangiography,percutaneous transhepatic cholangiography and drainage,or placement of stents.The technique was performed through an existing percutaneous transhepatic tract.Multiple specimens were obtained after passing the biopsy forceps or brush into a long 8-French sheath,and the specimens were fixed with formalin for pathologic or cytologic diagnosis.Statistical analysis was performed with the χ~2 test or Fisher exact probability,and P0.05 was considered to indicate a significant difference.Results All biopsy procedures were technically successful.Complications occurred in 2 patients with transient local biliary extravasation and no major complications occurred.The histopathologic diagnosis was acquired in 58 of (65 patients) with forceps biopsy.Pathologic reports included cholangioadenocarcinoma ((n=42),)cholangiosquamocarcinoma (n=1),pancreatic adenocarcinoma (n=2),hepatocellular carcinoma (n=2),metastatic carcinoma (n=5),hyperplasia in fibrous connective tissue (n=2),sclerosing cholangitis (n=1),biliary stone (n=1),zoogloea aggregation (n=1),chronic cholangitis (n=1),and negative results ((n=7).)The sensitivity rate of forceps biopsy was 89.23%.Sensitivity of biopsy in the 45 patients with cholangiocarcinoma was higher than in the 16 patients with malignant tumors other than cholangiocarcinoma (95.56% vs 68.75%,χ~2=5.919,P=0.015).The cyctologic diagnosis was acquired in 43 of 58 patients with brush biopsy.Pathologic reports included cholangioadenocarcinoma ((n=36),)cholangiosquam-ocarcinoma (n=1),pancreatic adenocarcinoma (n=1),hepatocellular carcinoma (n=2),metastatic carcinoma (n=2),zoogloea aggregation (n=1),and negative results (n=15).The sensitivity rate of brush biopsy was 74.14%.Sensitivity of brush in the 45 patients with cholangiocarcinoma was higher than in the 11 patients with malignant tumors other than cholangiocarcinoma (82.22% vs 45.45%,χ~2=4.563,P=0.033).Sensitivity of forceps biopsy in the 65 patients was higher than that of brush in the (58 patients) (χ~2=4.754,P=0.029).Conclusion Percutaneous transhepatic cholangiobiopsy is a safe and minimal invasive procedure with no pain and low complication that is easy to perform with no addition trauma through a transhepatic biliary drainage tract.It is an effective,economic,accurate,and reliable new approach,which is safe and easy to perform in acquiring the pathologic diagnosis worthy to spread extensively.