Effect and mechanism of bias voltage on microstructure and corrosion resistance of Cr x N y coatings in proton-exchange membrane fuel cells

Shuan Li,Song Li,Daogao Wu,Shuang Wang,Bingzheng Yang,Hongbo Yang,Xingguo Li,Xiaowei Zhang
DOI: https://doi.org/10.1016/j.vacuum.2024.113337
IF: 4
2024-06-04
Vacuum
Abstract:The key factor limiting the long-term commercial application of Cr x N y coatings in the PEMFC is that these coatings easily grow into coarse columnar crystals with subsequent microcracks and pinholes, leading to a sharp decrease in corrosion resistance performance. In this view, a series of different substrate bias voltages were applied to deal with this problem. The results demonstrated that with applying a −120 V bias voltage on the substrate, the adhesion strength is double that of the Cr x N y coating without bias voltage. In addition, the −120V-Cr x N y sample exhibits the lowest corrosion current density of 0.65 μA/cm 2 and a minimum ICR value of 5.87 mΩ cm 2 , thus highly meeting the U.S. DOE 2025 targets. Moreover, the Cr x N y coatings subjected to bias voltages ranging from −100 V to −140 V exhibit excellent durability and stability, with current densities that are 1-2 orders of magnitude lower compared to the 0V-Cr x N y coatings. Therefore, this work provides a novel approach to control the growth of columnar crystals in Cr x N y coatings for future PEMFC manufacturing processes, and has important reference value for the regulation of columnar crystals in other coatings such as TiN, NbN, AlN, etc.
materials science, multidisciplinary,physics, applied
What problem does this paper attempt to address?